within a raised access floor system to enhance airflow and improve targeted cooling, especially in high-density IT or server
environments.
Key Features:
1. High-Performance Fan Module
* Typically includes one or more centrifugal or axial fans.
* Airflow rated in CFM (Cubic Feet per Minute), ranging from 589 to over 2120 CFM.
2. Integration with Floor Panels
* Designed to fit standard raised floor tiles (e.g., 24" x 24").
* Can be placed in place of a regular floor tile without altering the floor grid.
3. Variable Speed Control
* Manual or automatic fan speed adjustment.
* Some units include thermostats or sensors to respond to temperature changes.
4. Targeted Cooling
* Directs cold air from the underfloor plenum to specific hot spots (e.g., server racks).
* Helps eliminate thermal dead zones and balance temperature distribution.
5. Power Options
* Typically powered by standard AC power (110-240V).
* Some models use DC fans for energy efficiency and quieter operation.
6. Safety & Monitoring Features
* May include fan failure alarms, temperature monitoring, or integration with BMS (Building Management System).
* Grille or mesh cover to prevent debris intrusion and ensure safe walking.
7. Energy Efficiency
* Enhances cooling only where needed, reducing overall HVAC load and operational cost.
Common Use Cases:
* Data centers
* Telecom rooms
* Laboratories
* High-density server deployments
Product name | Raised Floor Blower Cooling System Temperature Control Sensor Speed Adjustable |
Matching raised floor size | 600*600*30~50mm;Min floor finish height 300mm |
Material | Steel |
Equivalent cooling capacity
|
18kw |
Air supply angle | vertical |
Air volume | 1000~3600m³/h |
Fan |
EC high voltage brushless blower with soft start function
|
Temperature Control System |
There is a temperature control module control box, the fan and the floor are integrated, with automatic induction control. stepless speed regulation according to temperature changes, and setting of starting temperature, over-limit operating temperature, and alarm temperature
|
Temperature sensor probe |
Configure one piece and install it at the server exhaust port or floor vent, and the temperature accuracy reaches ±0.1C
|
Overall size | 600*600*200mm |
Power supply |
Dual power supply, one is connected to the mains power and the other is connected to the UPS.
When the mains power fails, it automatically switches to the UPS power supply
|
Communication Interface
|
Provides MODBUS communication protocol, enabling remote communication control, group control, and status inspection
|